Food Testing

Automatic Nitrogen/ Protein/Fat /Fiber Analyzer

  • Fully Automatic Nitrogen / Protein Analyzer

  • Automatic Scrubber

  • Automatic Nitrogen PC Interface Distillation System

  • Automatic Fat (oil) Extraction System (Soxhlet)

  • Fully Automated Fibre Estimation System

Fully Automatic Nitrogen/ Protein Analyzer

Fully Automatic Nitrogen / Protein Analyzer

MULTI - Functional Automatic Digestion System (Kjeldahl..COD..DIACID & TRIACID, Trace Metal)

ABC INC offers a complete solution for Kjeldahl analysis, made up of a mineralization unit, Suction and fume neutralization systems and Distillation/Titration Unit According to the Official methods (AOAC, EPA, DIN and ISO). Products Certified (ISO 9001: 2015, CE, ISO 17025)

Application:

Rapid Automatic Macro Block Nitrogen/ Protein Digestion System (Suitable for all type of Sample like solid & liquid Water, Pesticides, Fertilizers, Manure, waste water, sludge, urea, Bio Material, Fish Meal, Animal Feed, Fodder, Grain, Plant, Soil, food & feed, milk, skimmed Milk powder, Milk products, Confectionary, Agricultural, leather, Industrial effluents, Chemicals, Petrochemicals, Leather, Tissue, Paper pulp Chemicals, Leather, Tissue, Paper pulp & Many More).

System Info:

  • M/N:AI-KDIGB-12M: Superior Auto sequencing Microprocessor Based Twelve Sample Macro Tube Digestion Block With Programmable Controller Graphical LCD Display System.
  • Heaters: Rapid & High heating Casted Aluminum Heaters for Even Heating with Epoxy coating for acid resistance.
  • Macro Digestion tubes with capacity 300 ml volume.
  • MOC: Chemical Resistant Anti Corrosive Epoxy Powder coated long Life, Corrosion Free Heating Aluminum Blocks.
  • Customizable Program of sample selection library like soil, Plant, water, food, feed, Cereals, starch etc...

Features:

  • Inbuilt Auto Sequence allows 100 Intelligent Program System 12 Desire Ramp/Sequence Steps. Temperature Controller Range: Ambient to 500° C, Temperature Accuracy & stability:±0.5°C. Display views: Temperature present and set value, Time, Date, Real Time, Data Logger, Graphical Representation System, Time Selection 1 to 999 Minutes.
  • Automatic Scrubber ON/OFF , Auto Temperature Calibration etc.
  • Real time monitoring of process parameter Process resume from stop and power failure for continuous operation, Chemical Resist with Epoxy coating for acid resistance.
  • Two tier console: Compact design to place Insert rack and Manifold Rack with exhaust manifold & Drip tray in the above part of digestion system.
  • All essential accessories like SS Insert Rack, Drip Tray, and Heat Shield plate for temperature cut-off, Exhaust Teflon manifold suction Assembly for safe removal of acid fumes will be provided with the unit As standard accessories with indicators to save the power, Auto alarm for user’s attention Acoustic and indicator lamps showing when the unit reaches the end of final cycle. Auto Shutdown facility after completion of Digestion Cycle with indicators with visual Display, Lighting facility Auto alarm for user’s attention, Over Temperature Protection, Auto sensor Break Protection Auto Over temp. Cut Off, Acoustic and Visual error Indication & Damage Probe Detection.
  • Password Login Features, Automatic sample Cooling Facility after Digestion Completion, Auto Run Alert etc.
Automatic Scrubber

Automatic Scrubber

  • Model AI-KJ-SCRB: Acid Neutralizer Four Stage Scrubbing System. Number of Stage gas Scrubbing System: FOUR
  • First Stage: Acid Trap Condensation Second Stage: Neutralization in Alkali Third stage: Neutralization in water
  • Fourth Stage: Adsorption and Redox Reaction
  • Non-Corrosive – chemical Resistant inbuilt Magnetic PVC Self priming water recirculation pump in 8 litres tank avoids requirement of running water during digestion
  • Vacuum source: Non corrosive centrifugal suction Aspirator filter pump for vacuum Stainless Steel Tank of capacity 8 Litres.
  • Automatic water Level Indicator to view water level in Stainless Steel tank Externally
  • Facility of Scrubber Automatically shut down and auto start up
  • Chemical Resist with Epoxy coating for acid resistance

Accessories:

  • Borosilicate alkali with 2 litre Container.
  • Borosilicate water with 2 litre Container.
Automatic Nitrogen PC Interface Distillation System

Automatic Nitrogen PC Interface Distillation System

(Kjeldahl....COD...DIACID & TRIACID, Trace Metal)

M/N AI-KjelDIST-AF-DD : ADVANCED FULLY AUTO Nitrogen PC Compatible Dual DISTILLATION SYSTEM (ISO 9001:2015 & CE Certified) (The Rapid Fully Auto Run Completely Microprocessor Programmable Based PC Compatible Auto Sequence Operation LCD Display Distillation System with 100 Programmable users in built Software) No. of Samples: Two at a Time. Mode of operation: Single / both Simultaneously.

Application:

Suitable for all type of sample like Solid & liquid milk, skimmed milk powder, milk products, Confectionary, Water, Pesticides, Fertilizers, Manure, waste water, urea, Bio Material, Fish Meal, Animal Feed, Fodder, Grain, Plant, Soil, food & feed, Agricultural, Industrial, Sludge, Petrochemicals, Chemicals, Leather, Paper pulp and many more.

Programable Features:

  • Auto Addition of Boric acid (Receiver Solution)
  • Auto Sample Selection Library
  • Auto Addition of Sample Dilution
  • Auto Duration of React time
  • Auto Duration for delay time
  • Auto Addition of NaOH (Alkali)
  • Auto Duration of Neutralization.
  • Auto Addition of water Steam injection.
  • Auto Duration for Residue Removal /Tube Drain
  • Auto Distillate control with adjustable volume Steps
  • Auto Duration of Sample Settle Time.
  • Auto Process over Intimation with alarm
  • Auto alarm for Sequence steps
  • Auto Titration Connectivity feature for future up gradation

Features:

  • Independent stainless steel non corrosive steam generator, Expansion Vessel & cooling water Condenser. Flow diagram display to show live auto sequencing steps at each stage of process, Data table export to excel. Microprocessor Programmable Auto Distillate control with adjustable volume for determination of Available nitrogen. Automatic microprocessor sensor detects the ‘No water’ in condensers’ system will intimates with auto user alarm and Visual indication. Continuously Measured Temperature is Displayed Digitally.
  • If "No water Condition" happens Auto deactivation of operation after Thirty seconds with warning in case of user non availability in condenser & steam generator.
  • Auto Microprocessor Programmable Monitoring & measuring of high temperature protection with help of Platinum. sensor & alert intimation for User attention Temperature display in the View of Direct LCD Bright Display Auto Reagent level sensor with alarm Indication in the time of adding reagents
  • Auto Pressurized Steam Generate- BOILER: High grade 316 A. Stainless steel non corrosive steam Generator
  • Inbuilt Mini printer for Direct Print out of results without connecting to PC Automatic water level monitoring & precise Peristaltic pump for Accurate reagents addition Auto sequence steps Execute in the view of flow diagram in Touch screen display Adjustable steam power from 5 to 100%, Auto online water saving mechanism Nitrogen level: 1 to 200 mg Nitrogen,Nitrogen Reproducibility: + 0.1% RSD,Nitrogen Recovery: >99.5%, Electrical Requirement 220-230V/50Hz.
  • Auto tube inserts error indication
  • Safety Auto Door opens warning alarm with visual Indication Auto Deactivation of System Error Diagnosis, Etc.
Automatic Fat (oil) Extraction System (Soxhlet)

Automatic Fat (oil) Extraction System (Soxhlet)

Application:

Suitable for determination of capacity of quantitative separation total fat/oil content in all type of Solid & Semi Solid Feed & food sample, Milk Powder & Dairy products, Cereals & its products, Meat & Meat Products, Oil & oil Seeds, Lipids in egg & egg Products, Plant, fodders sample & Many More.

System Description:

Model: AI-SOX-6 Six samples Automatic Fat / oil 5 Step Superior Auto Sequence Solvent Extraction System with auto time / temperature Microprocessor Programming control With LCD Digital Display system. Instrument based on official 'RANDALL' method accepted by AOAC, GLP, ISO, DIN have capability to perform unattended operation and microprocessor programmable based solvent recovery system All materials are in contact with solvents. We are using suitable Polytetrafluoroethylene (PTFE) high grade material in the solvent area.

MOC:

Epoxy painted stainless-steel structure to prevent corrosion

Sample Volume:

0.25 to 10 gm depend upon the sample. Vessel Capacity:125-150 ml Volume

Heaters:

High Grade Casted Aluminum Alloy Heaters for Uniform Heating with SS Splash Plate

Features:

  • Microprocessor Based LCD Display System read out for Temperature & Time. Accuracy: ± 1%, Reproducibility: ± 1% Relative at 5% - 30 % Oil/Fat Measuring Range: 0.1 to 100% Oil/Fat
  • Inbuilt LCD Display System read out of sample selection library Temperature Control Range: 350 ° Temperature Accuracy: ± 0.1° C. Time Selection 1 to 999 Minutes 1 minute step
  • 10 Intelligent user storage program more than 5 Desire Ramp/Sequence steps
  • Auto sequence extraction with auto phase changeover of boiling, condensation, rinsing and recovery phases, Auto Alarm for recovery phase, Auto switch at end of extraction procedure.
  • Solvent Recovery: 70 % & above depend upon the sample
  • Extraction beakers & Nitro Cellulose thimble Size: (25 mm dia X 80mm L) or more Speed of extraction 30 - 60 min depend upon sample

Safety Features:

  • Warning sign Adequately displayed in Digital display
  • Auto calibration of heating temperature
  • Acoustic and Visual Error Indication and Sensor Break.
  • Auto heater cut-off facility with indicators to save the power.
  • Auto alarm for user’s attention
Fully Automated Fibre Estimation System

Fully Automated Fibre Estimation System

Application:

Suitable for faster, safer, and high throughput fibre extraction from food related samples Determination of Fiber content in all type of Feed & food sample, related parameters in plants materials, Cereals & its products, Seeds & Many More through acidic hydrolysis system.

System Description:

Model:AI-FIB-6-Six samples Automatic PC Compatible Superior Auto Sequence Fiber Estimation System with auto Time/Temperature Microprocessor Programming Control Hot Extraction Built in Heating Filtration with LCD Digital Display. Sample size: Depends upon the sample less than 0.1 to 4 gms. Heater: high grade ceramic inbuilt infrared heaters with heat reflector SS Splash plate. Heater Control: Automatic Microprocessor program controller.

Sample Loading: Individual non corrosive stainless-steel spring Easy Mechanical Controls for sample loading.

Features:

  • sequential extractions including boiling, rinsing and filtration performed under reproducible & controlled System.
  • Temperature Control Range: Room temperature to 450°C, Temperature Accuracy: ±0.5°C Microprocessor Based LCD Display System read out for Temperature & Time Measuring range: 0.1 – 100% Reproducibility: ± 1%, Relative at 5% - 30 % fiber level 10 Intelligent user storage program more than 5 Desire Ramp/Sequence steps Heater Control: Automatic Microprocessor Program Controller.
  • In Built Pre Heating facility for acid/ alkali with PID control Borosilicate reagent heating flask with Handle.
  • Extractor: Marked borosilicate extraction vessel with borosilicate reflux condenser
  • Vacuum source – Fibro system with self-priming pump connected to water suction glass filter pump for rapid filtrations.
  • Microprocessor Based Specialized Electrical air pump for reclogging Individual valve: Individual Non-Corrosive valves for Draining.
  • vacuum pressure, reverse air stream & reagent addition, solvent dehydration of fiber residues. Reagent Addition directly from the top of the extractor
  • Control Valve: Individual control valves for vacuum & reverse air stream
  • Separate isolated Temperature Controller in a control tower for digestion heat zone and acid reaction zone High grade Silica glass Crucible with P2 (P100) Disc ,40-90 Warning sign Adequately displayed in Digital display
  • Auto calibration of heating temperature
  • Acoustic and Visual Error Indication and Sensor Break.
  • Auto heater cut-off facility with indicators to save the power.
  • Auto alarm for user’s attention.
  • Warning sign Adequately displayed in Digital display, Auto calibration of heating temperature, Automatic safety features like over temperature protection, Auto Error Indication and Sensor Break. Auto heater cut-off facility with indicators to save the power, Auto alarm for user’s attention Acoustic and indicator lamps showing when the unit reaches the end of final cycle.
Location
call
whatsapp